SCSI Internal (Single-ended)

SCSI=Small Computer System Interface.
Based on an original design by Shugart Associates. SCSI was ratified in 1986.


(At the controller & harddisk)

(At the cable)

50 PIN IDC MALE at the controller & harddisk.
50 PIN IDC FEMALE at the cable.
 
Pin
Name
Dir
Description
2
DB0
< >
Data Bus 0
4
DB1
< >
Data Bus 1
6
DB2
< >
Data Bus 2
8
DB3
< >
Data Bus 3
10
DB4
< >
Data Bus 4
12
DB5
< >
Data Bus 5
14
DB6
< >
Data Bus 6
16
DB7
< >
Data Bus 7
18
PARITY
< >
Data Parity (odd Parity)
20
GND
------
Ground
22
GND
------
Ground
24
GND
------
Ground
26
TMPWR
< >
Termination Power
28
GND
------
Ground
30
GND
------
Ground
32
/ATN
<
Attention
34
GND
------
Ground
36
/BSY
< >
Busy
38
/ACK
<
Acknowledge
40
/RST
< >
Reset
42
/MSG
>
Message
44
/SEL
< >
Select
46
/C/D
>
Control/Data
48
/REQ
>
Request
50
/I/O
>
Input/Output


SCSI Internal (Differential)


      (at the controller & harddisk.)                                                   (At the cable)

50 PIN IDC MALE at the controller & harddisk.
50 PIN IDC FEMALE at the cable.
 
Pin
Name
Dir
Description
01
GND
------
Ground
02
GND
------
Ground
03
+DB0
< >
+Data Bus 0
04
-DB0
< >
-Data Bus 0
05
+DB1
< >
+Data Bus 1
06
-DB1
< >
-Data Bus 1
07
+DB2
< >
+Data Bus 2
08
-DB2
< >
-Data Bus 2
09
+DB3
< >
+Data Bus 3
10
-DB3
< >
-Data Bus 3
11
+DB4
< >
+Data Bus 4
12
-DB4
< >
-Data Bus 4
13
+DB5
< >
+Data Bus 5
14
-DB5
< >
-Data Bus 5
15
+DB6
< >
+Data Bus 6
16
-DB6
< >
-Data Bus 6
17
+DB7
< >
+Data Bus 7
18
-DB7
< >
-Data Bus Parity7
19
+DBP
< >
+Data Bus Parity (odd Parity)
20
-DBP
< >
-Data Bus Parity (odd Parity)
21
DIFFSENS
?
???
22
GND
------
Ground
23
res
-
Reserved
24
res
-
Reserved
25
TERMPWR
< >
Termination Power
26
TERMPWR
< >
Termination Power
27
res
-
Reserved
28
res
-
Reserved
29
+ATN
<
+Attention
30
-ATN
<
-Attention
31
GND
------
Ground
32
GND
------
Ground
33
+BSY
< >
+Bus is busy
34
-BSY
< >
-Bus is busy
35
+ACK
<
+Acknowledge
36
-ACK
<
-Acknowledge
37
+RST
< >
+Reset
38
-RST
< >
-Reset
39
+MSG
>
+Message
40
-MSG
>
-Message
41
+SEL
< >
+Select
42
-SEL
< >
-Select
43
+C/D
>
+Control or Data
44
-C/D
>
-Control or Data
45
+REQ
>
+Request
46
-REQ
>
-Request
47
+I/O
>
+In/Out
48
-I/O
>
-In/Out
49
GND
------
Ground
50
GND
------
Ground



 

SCSI-II External Hi D-Sub (Single-ended)

(At the controller & devices).
 

(To the cable)

50 PIN HI-DENSITY D-SUB FEMALE at the controller & devices.
50 PIN HI-DENSITY D-SUB MALE at the cable.
 
Pin
Name
Dir
Description
1-25
GND
------
Ground
26
DB0
< >
Data Bus 0
27
DB1
< >
Data Bus 1
28
DB2
< >
Data Bus 2
29
DB3
< >
Data Bus 3
30
DB4
< >
Data Bus 4
31
DB5
< >
Data Bus 5
32
DB6
< >
Data Bus 6
33
DB7
< >
Data Bus 7
34
PARITY
< >
Data Parity (odd Parity)
35
GND
------
Ground
36
GND
------
Ground
37
GND
------
Ground
38
TMPWR
< >
Termination Power
39
GND
------
Ground
40
GND
------
Ground
41
/ATN
<
Attention
42
n/c
-
Not connected
43
/BSY
< >
Busy
44
/ACK
<
Acknowledge
45
/RST
< >
Reset
46
/MSG
>
Message
47
/SEL
< >
Select
48
/C/D
>
Control/Data
49
/REQ
>
Request
50
/I/O
>
Input/Output

 

SCSI-II External Hi D-Sub (Differential)

(At the controller & devices)


(To the cable)

50 PIN HI-DENSITY D-SUB FEMALE at the controller & devices.
50 PIN HI-DENSITY D-SUB MALE at the cable.
 
Pin
Name
Dir
Description
01
GND
-----
Ground
02
+DB0
< >
+Data Bus 0
03
+DB1
< >
+Data Bus 1
04
+DB2
< >
+Data Bus 2
05
+DB3
< >
+Data Bus 3
06
+DB4
< >
+Data Bus 4
07
+DB5
< >
+Data Bus 5
08
+DB6
< >
+Data Bus 6
09
+DB7
< >
+Data Bus 7
10
+DBP
< >
+Data Bus Parity (odd Parity)
11
DIFFSENS
?
???
12
res
-
Reserved
13
TERMPWR
< >
Termination Power
14
res
-
Reserved
15
+ATN
<
+Attention
16
GND
-----
Ground
17
+BSY
< >
+Bus is busy
18
+ACK
<
+Acknowledge
19
+RST
< >
+Reset
20
+MSG
>
+Message
21
+SEL
< >
+Select
22
+C/D
>
+Control or Data
23
+REQ
>
+Request
24
+I/O
>
+In/Out
25
GND
-----
Ground
26
GND
-----
Ground
27
-DB0
< >
-Data Bus 0
28
-DB1
< >
-Data Bus 1
29
-DB2
< >
-Data Bus 2
30
-DB3
< >
-Data Bus 3
31
-DB4
< >
-Data Bus 4
32
-DB5
< >
-Data Bus 5
33
-DB6
< >
-Data Bus 6
34
-DB7
< >
-Data Bus Parity7
35
-DBP
< >
-Data Bus Parity (odd Parity)
36
GND
-----
Ground
37
res
-
Reserved
38
TERMPWR
< >
Termination Power
39
res
-
Reserved
40
-ATN
<
-Attention
41
GND
-----
Ground
42
-BSY
< >
-Bus is busy
43
-ACK
<
-Acknowledge
44
-RST
< >
-Reset
45
-MSG
>
-Message
46
-SEL
< >
-Select
47
-C/D
>
-Control or Data
48
-REQ
>
-Request
49
-I/O
>
-In/Out
50
GND
-----
Ground



 

SCSI External D-Sub (PC/Amiga/Mac)

(At the controller)


At (the cable)
25 PIN D-SUB FEMALE at the controller.
25 PIN D-SUB MALE at the cable.
 
Pin
Name
Dir
Description
1
/REQ
>
Request
2
/MSG
>
Message
3
I/O
>
Input/Output
4
/RST
< >
Reset
5
/ACK
<
Acknowledge
6
BSY
< >
Busy
7
GND
-----
Ground
8
DB0
< >
Data Bus 0
9
GND
-----
Ground
10
DB3
< >
Data Bus 3
11
DB5
< >
Data Bus 5
12
DB6
< >
Data Bus 6
13
DB7
< >
Data Bus 7
14
GND
-----
Ground
15
C/D
>
Control/Data
16
GND
-----
Ground
17
/ATN
<
Attention
18
GND
-----
Ground
19
/SEL
< >
Select
20
PARITY
< >
Data Parity
21
DB1
< >
Data Bus 1
22
DB2
< >
Data Bus 2
23
DB4
< >
Data Bus 4
24
GND
-----
Ground
25
TMPWR
< >
Termination Power


SCSI External D-Sub (Future Domain)

Seems to be available on some Future Domain SCSI-controllers only.

(At the controller)

(At the cable)

25 PIN D-SUB FEMALE at the controller.
25 PIN D-SUB MALE at the cable.
 
Pin
Name
Dir
Description
1
GND
-----
Ground
2
DB1
< >
Data Bus 1
3
DB3
< >
Data Bus 3
4
DB5
< >
Data Bus 5
5
DB7
< >
Data Bus 7
6
GND
-----
Ground
7
/SEL
< >
Select
8
GND
-----
Ground
9
TMPWR
< >
Termination Power
10
/RST
< >
Reset
11
C/D
>
Control/Data
12
I/O
>
Input/Output
13
GND
-----
Ground
14
DB0
< >
Data Bus 0
15
DB2
< >
Data Bus 2
16
DB4
< >
Data Bus 4
17
DB6
< >
Data Bus 6
18
PARITY
< >
Data Parity
19
GND
-----
Ground
20
/ATN
<
Attention
21
/MSG
>
Message
22
/ACK
<
Acknowledge
23
BSY
< >
Busy
24
/REQ
>
Request
25
GND
-----
Ground


Any information used is at your own risk.
Do take proper precautions when working with electronic parts,
some can hold electrical discharges

All rights reserved 1999

We are releasing more products soon. Please visit often!

All rights reserved. Copyright BudgetWare Marketing Group, Inc.
"Cisco is a property and trademark of the Cisco Corporation. Novell and NetWare trademarks are property of the Novell Corporation.
Microsoft, NT, and Windows trademarks are property of the Microsoft
Corporation. Any and all trademarks mentioned are property of their
respective company, and does not imply or represent any affiliation
of BudgetWare Marketing Group, Inc.- AudioWhiz.com to those companies."