SCSI Internal (Single-ended)
SCSI=Small Computer System Interface.
Based on an original design by Shugart Associates. SCSI was
ratified in 1986.
(At the controller & harddisk)
(At the cable)
50 PIN IDC MALE at the controller & harddisk.
50 PIN IDC FEMALE at the cable.
|
Pin
|
Name
|
Dir
|
Description
|
|
2
|
DB0
|
< >
|
Data Bus 0
|
|
4
|
DB1
|
< >
|
Data Bus 1
|
|
6
|
DB2
|
< >
|
Data Bus 2
|
|
8
|
DB3
|
< >
|
Data Bus 3
|
|
10
|
DB4
|
< >
|
Data Bus 4
|
|
12
|
DB5
|
< >
|
Data Bus 5
|
|
14
|
DB6
|
< >
|
Data Bus 6
|
|
16
|
DB7
|
< >
|
Data Bus 7
|
|
18
|
PARITY
|
< >
|
Data Parity (odd Parity)
|
|
20
|
GND
|
------
|
Ground
|
|
22
|
GND
|
------
|
Ground
|
|
24
|
GND
|
------
|
Ground
|
|
26
|
TMPWR
|
< >
|
Termination Power
|
|
28
|
GND
|
------
|
Ground
|
|
30
|
GND
|
------
|
Ground
|
|
32
|
/ATN
|
<
|
Attention
|
|
34
|
GND
|
------
|
Ground
|
|
36
|
/BSY
|
< >
|
Busy
|
|
38
|
/ACK
|
<
|
Acknowledge
|
|
40
|
/RST
|
< >
|
Reset
|
|
42
|
/MSG
|
>
|
Message
|
|
44
|
/SEL
|
< >
|
Select
|
|
46
|
/C/D
|
>
|
Control/Data
|
|
48
|
/REQ
|
>
|
Request
|
|
50
|
/I/O
|
>
|
Input/Output
|
SCSI Internal (Differential)

(at the controller &
harddisk.)
(At the cable)
50 PIN IDC MALE at the controller & harddisk.
50 PIN IDC FEMALE at the cable.
|
Pin
|
Name
|
Dir
|
Description
|
|
01
|
GND
|
------
|
Ground
|
|
02
|
GND
|
------
|
Ground
|
|
03
|
+DB0
|
< >
|
+Data Bus 0
|
|
04
|
-DB0
|
< >
|
-Data Bus 0
|
|
05
|
+DB1
|
< >
|
+Data Bus 1
|
|
06
|
-DB1
|
< >
|
-Data Bus 1
|
|
07
|
+DB2
|
< >
|
+Data Bus 2
|
|
08
|
-DB2
|
< >
|
-Data Bus 2
|
|
09
|
+DB3
|
< >
|
+Data Bus 3
|
|
10
|
-DB3
|
< >
|
-Data Bus 3
|
|
11
|
+DB4
|
< >
|
+Data Bus 4
|
|
12
|
-DB4
|
< >
|
-Data Bus 4
|
|
13
|
+DB5
|
< >
|
+Data Bus 5
|
|
14
|
-DB5
|
< >
|
-Data Bus 5
|
|
15
|
+DB6
|
< >
|
+Data Bus 6
|
|
16
|
-DB6
|
< >
|
-Data Bus 6
|
|
17
|
+DB7
|
< >
|
+Data Bus 7
|
|
18
|
-DB7
|
< >
|
-Data Bus Parity7
|
|
19
|
+DBP
|
< >
|
+Data Bus Parity (odd Parity)
|
|
20
|
-DBP
|
< >
|
-Data Bus Parity (odd Parity)
|
|
21
|
DIFFSENS
|
?
|
???
|
|
22
|
GND
|
------
|
Ground
|
|
23
|
res
|
-
|
Reserved
|
|
24
|
res
|
-
|
Reserved
|
|
25
|
TERMPWR
|
< >
|
Termination Power
|
|
26
|
TERMPWR
|
< >
|
Termination Power
|
|
27
|
res
|
-
|
Reserved
|
|
28
|
res
|
-
|
Reserved
|
|
29
|
+ATN
|
<
|
+Attention
|
|
30
|
-ATN
|
<
|
-Attention
|
|
31
|
GND
|
------
|
Ground
|
|
32
|
GND
|
------
|
Ground
|
|
33
|
+BSY
|
< >
|
+Bus is busy
|
|
34
|
-BSY
|
< >
|
-Bus is busy
|
|
35
|
+ACK
|
<
|
+Acknowledge
|
|
36
|
-ACK
|
<
|
-Acknowledge
|
|
37
|
+RST
|
< >
|
+Reset
|
|
38
|
-RST
|
< >
|
-Reset
|
|
39
|
+MSG
|
>
|
+Message
|
|
40
|
-MSG
|
>
|
-Message
|
|
41
|
+SEL
|
< >
|
+Select
|
|
42
|
-SEL
|
< >
|
-Select
|
|
43
|
+C/D
|
>
|
+Control or Data
|
|
44
|
-C/D
|
>
|
-Control or Data
|
|
45
|
+REQ
|
>
|
+Request
|
|
46
|
-REQ
|
>
|
-Request
|
|
47
|
+I/O
|
>
|
+In/Out
|
|
48
|
-I/O
|
>
|
-In/Out
|
|
49
|
GND
|
------
|
Ground
|
|
50
|
GND
|
------
|
Ground
|
SCSI-II External Hi D-Sub (Single-ended)
(At the controller
& devices).
(To the cable)
50 PIN HI-DENSITY D-SUB FEMALE at the controller &
devices.
50 PIN HI-DENSITY D-SUB MALE at the cable.
|
Pin
|
Name
|
Dir
|
Description
|
|
1-25
|
GND
|
------
|
Ground
|
|
26
|
DB0
|
< >
|
Data Bus 0
|
|
27
|
DB1
|
< >
|
Data Bus 1
|
|
28
|
DB2
|
< >
|
Data Bus 2
|
|
29
|
DB3
|
< >
|
Data Bus 3
|
|
30
|
DB4
|
< >
|
Data Bus 4
|
|
31
|
DB5
|
< >
|
Data Bus 5
|
|
32
|
DB6
|
< >
|
Data Bus 6
|
|
33
|
DB7
|
< >
|
Data Bus 7
|
|
34
|
PARITY
|
< >
|
Data Parity (odd Parity)
|
|
35
|
GND
|
------
|
Ground
|
|
36
|
GND
|
------
|
Ground
|
|
37
|
GND
|
------
|
Ground
|
|
38
|
TMPWR
|
< >
|
Termination Power
|
|
39
|
GND
|
------
|
Ground
|
|
40
|
GND
|
------
|
Ground
|
|
41
|
/ATN
|
<
|
Attention
|
|
42
|
n/c
|
-
|
Not connected
|
|
43
|
/BSY
|
< >
|
Busy
|
|
44
|
/ACK
|
<
|
Acknowledge
|
|
45
|
/RST
|
< >
|
Reset
|
|
46
|
/MSG
|
>
|
Message
|
|
47
|
/SEL
|
< >
|
Select
|
|
48
|
/C/D
|
>
|
Control/Data
|
|
49
|
/REQ
|
>
|
Request
|
|
50
|
/I/O
|
>
|
Input/Output
|
SCSI-II External Hi D-Sub (Differential)
(At the controller & devices)
(To the cable)
50 PIN HI-DENSITY D-SUB FEMALE at the controller &
devices.
50 PIN HI-DENSITY D-SUB MALE at the cable.
|
Pin
|
Name
|
Dir
|
Description
|
|
01
|
GND
|
-----
|
Ground
|
|
02
|
+DB0
|
< >
|
+Data Bus 0
|
|
03
|
+DB1
|
< >
|
+Data Bus 1
|
|
04
|
+DB2
|
< >
|
+Data Bus 2
|
|
05
|
+DB3
|
< >
|
+Data Bus 3
|
|
06
|
+DB4
|
< >
|
+Data Bus 4
|
|
07
|
+DB5
|
< >
|
+Data Bus 5
|
|
08
|
+DB6
|
< >
|
+Data Bus 6
|
|
09
|
+DB7
|
< >
|
+Data Bus 7
|
|
10
|
+DBP
|
< >
|
+Data Bus Parity (odd Parity)
|
|
11
|
DIFFSENS
|
?
|
???
|
|
12
|
res
|
-
|
Reserved
|
|
13
|
TERMPWR
|
< >
|
Termination Power
|
|
14
|
res
|
-
|
Reserved
|
|
15
|
+ATN
|
<
|
+Attention
|
|
16
|
GND
|
-----
|
Ground
|
|
17
|
+BSY
|
< >
|
+Bus is busy
|
|
18
|
+ACK
|
<
|
+Acknowledge
|
|
19
|
+RST
|
< >
|
+Reset
|
|
20
|
+MSG
|
>
|
+Message
|
|
21
|
+SEL
|
< >
|
+Select
|
|
22
|
+C/D
|
>
|
+Control or Data
|
|
23
|
+REQ
|
>
|
+Request
|
|
24
|
+I/O
|
>
|
+In/Out
|
|
25
|
GND
|
-----
|
Ground
|
|
26
|
GND
|
-----
|
Ground
|
|
27
|
-DB0
|
< >
|
-Data Bus 0
|
|
28
|
-DB1
|
< >
|
-Data Bus 1
|
|
29
|
-DB2
|
< >
|
-Data Bus 2
|
|
30
|
-DB3
|
< >
|
-Data Bus 3
|
|
31
|
-DB4
|
< >
|
-Data Bus 4
|
|
32
|
-DB5
|
< >
|
-Data Bus 5
|
|
33
|
-DB6
|
< >
|
-Data Bus 6
|
|
34
|
-DB7
|
< >
|
-Data Bus Parity7
|
|
35
|
-DBP
|
< >
|
-Data Bus Parity (odd Parity)
|
|
36
|
GND
|
-----
|
Ground
|
|
37
|
res
|
-
|
Reserved
|
|
38
|
TERMPWR
|
< >
|
Termination Power
|
|
39
|
res
|
-
|
Reserved
|
|
40
|
-ATN
|
<
|
-Attention
|
|
41
|
GND
|
-----
|
Ground
|
|
42
|
-BSY
|
< >
|
-Bus is busy
|
|
43
|
-ACK
|
<
|
-Acknowledge
|
|
44
|
-RST
|
< >
|
-Reset
|
|
45
|
-MSG
|
>
|
-Message
|
|
46
|
-SEL
|
< >
|
-Select
|
|
47
|
-C/D
|
>
|
-Control or Data
|
|
48
|
-REQ
|
>
|
-Request
|
|
49
|
-I/O
|
>
|
-In/Out
|
|
50
|
GND
|
-----
|
Ground
|
SCSI External D-Sub (PC/Amiga/Mac)
(At the controller)
At (the cable)
25 PIN D-SUB FEMALE at the controller.
25 PIN D-SUB MALE at the cable.
|
Pin
|
Name
|
Dir
|
Description
|
|
1
|
/REQ
|
>
|
Request
|
|
2
|
/MSG
|
>
|
Message
|
|
3
|
I/O
|
>
|
Input/Output
|
|
4
|
/RST
|
< >
|
Reset
|
|
5
|
/ACK
|
<
|
Acknowledge
|
|
6
|
BSY
|
< >
|
Busy
|
|
7
|
GND
|
-----
|
Ground
|
|
8
|
DB0
|
< >
|
Data Bus 0
|
|
9
|
GND
|
-----
|
Ground
|
|
10
|
DB3
|
< >
|
Data Bus 3
|
|
11
|
DB5
|
< >
|
Data Bus 5
|
|
12
|
DB6
|
< >
|
Data Bus 6
|
|
13
|
DB7
|
< >
|
Data Bus 7
|
|
14
|
GND
|
-----
|
Ground
|
|
15
|
C/D
|
>
|
Control/Data
|
|
16
|
GND
|
-----
|
Ground
|
|
17
|
/ATN
|
<
|
Attention
|
|
18
|
GND
|
-----
|
Ground
|
|
19
|
/SEL
|
< >
|
Select
|
|
20
|
PARITY
|
< >
|
Data Parity
|
|
21
|
DB1
|
< >
|
Data Bus 1
|
|
22
|
DB2
|
< >
|
Data Bus 2
|
|
23
|
DB4
|
< >
|
Data Bus 4
|
|
24
|
GND
|
-----
|
Ground
|
|
25
|
TMPWR
|
< >
|
Termination Power
|
SCSI External D-Sub (Future Domain)
Seems to be available on some Future Domain SCSI-controllers
only.
(At the controller)
(At the cable)
25 PIN D-SUB FEMALE at the controller.
25 PIN D-SUB MALE at the cable.
|
Pin
|
Name
|
Dir
|
Description
|
|
1
|
GND
|
-----
|
Ground
|
|
2
|
DB1
|
< >
|
Data Bus 1
|
|
3
|
DB3
|
< >
|
Data Bus 3
|
|
4
|
DB5
|
< >
|
Data Bus 5
|
|
5
|
DB7
|
< >
|
Data Bus 7
|
|
6
|
GND
|
-----
|
Ground
|
|
7
|
/SEL
|
< >
|
Select
|
|
8
|
GND
|
-----
|
Ground
|
|
9
|
TMPWR
|
< >
|
Termination Power
|
|
10
|
/RST
|
< >
|
Reset
|
|
11
|
C/D
|
>
|
Control/Data
|
|
12
|
I/O
|
>
|
Input/Output
|
|
13
|
GND
|
-----
|
Ground
|
|
14
|
DB0
|
< >
|
Data Bus 0
|
|
15
|
DB2
|
< >
|
Data Bus 2
|
|
16
|
DB4
|
< >
|
Data Bus 4
|
|
17
|
DB6
|
< >
|
Data Bus 6
|
|
18
|
PARITY
|
< >
|
Data Parity
|
|
19
|
GND
|
-----
|
Ground
|
|
20
|
/ATN
|
<
|
Attention
|
|
21
|
/MSG
|
>
|
Message
|
|
22
|
/ACK
|
<
|
Acknowledge
|
|
23
|
BSY
|
< >
|
Busy
|
|
24
|
/REQ
|
>
|
Request
|
|
25
|
GND
|
-----
|
Ground
|
Any
information used is at your own risk.
Do take proper precautions when working with electronic parts,
some can hold electrical discharges
All
rights reserved 1999
|